In short
If the host lives in the home and the guest rooms total 50㎡ or less, the home is generally treated as an ordinary residence under the Fire Service Act. If the host is absent or the guest rooms exceed 50㎡, it is generally treated like a hotel or ryokan, which can require an automatic fire alarm system, exit signs and flame-retardant items. Consult the local fire station before you buy, lease or start work.
The short answer
Most minpaku run by owners who live elsewhere, including owners abroad, are host-absent. In that case, fire safety rules for hotels and ryokan generally apply to the unit, even though the building remains a home for other purposes. The required equipment differs by property, so the practical first step is a consultation at the fire station that covers the address. → Facilities and Fire Safety
Host-present vs. host-absent
Fire departments classify a minpaku by whether the host lives there and by the guest room area. Yokohama City's fire bureau summarizes it as follows, and the Tokyo Fire Department's Q&A uses the same criteria:
| Situation | Treatment under the Fire Service Act |
|---|---|
| Host lives there, guest rooms 50㎡ or less | Residence |
| Host lives there, guest rooms over 50㎡ | Hotel or ryokan (item 5-i of the Enforcement Order's Annex Table 1) |
| Host absent | Hotel or ryokan, regardless of guest room area |
The Tokyo Fire Department's Q&A adds that in a building with both a residence and guest rooms, the classification depends on which part is larger: where the guest rooms exceed 50㎡ but the residence is larger, the building becomes mixed use (item 16-i). Even when the home is treated as a residence, evacuation route information is required under the Private Lodging Business Act, and the national safety guide's Q&A asks for residential fire alarms in guest rooms unless an automatic fire alarm system is installed.
Equipment commonly required
For a home treated as a hotel or ryokan, the Tokyo Fire Department's Q&A gives these examples:
- Automatic fire alarm: for a one- or two-story detached house, an alarm system for specified small-scale facilities (特定小規模施設用自動火災報知設備); for three stories or a basement, generally a standard automatic fire alarm system
- Exit signs at exits, corridors and stairs (some locations may be exempt where visibility is clear)
- Flame-retardant curtains and carpets
- An evacuation route diagram posted in each guest room
- A fire extinguisher in the kitchen; for 150㎡ or more of floor area, extinguishers are required throughout the building
- A fire prevention manager if the capacity is 30 people or more
Where the home is treated as a residence, the national safety guide's Q&A notes that interconnected residential fire alarms are desirable. Each person with management authority in a building needs their own fire prevention manager where one is required, and the qualification comes from a fire prevention management course; the Tokyo Fire Department does not accept that filing by mail.
Separately, the national minpaku safety guidelines require building safety measures such as emergency lighting in guest rooms and along evacuation routes, depending on guest room area and whether the host is absent. Fire department requirements and these building safety measures are checked separately.
Condominiums and apartment buildings
According to the Tokyo Fire Department's Q&A:
- If the unit stays a residence and residential fire alarms are installed, no new equipment is required
- If the unit is treated as a lodging facility and the building becomes mixed use, exit signs and flame-retardant items are typically required, and in some cases an automatic fire alarm system
- A special provision for apartment buildings may allow existing equipment in the residential part to remain unchanged
- If non-residential uses exceed 10% of the total floor area and 300㎡, additional systems such as sprinklers may become necessary for the building
- Stricter rules apply where a building has only one indoor staircase and guest rooms are on a basement level or the third floor or above
Because a single unit can affect the whole building, involve the management association early. → Condominium bylaws
Consult the fire station early: compliance notice and filings
- Consult the fire station before you sign, and in parallel with the ward's public health center
- The fire station can issue a fire law compliance notice (消防法令適合通知書) after checking the property. What the ward asks you to attach differs: Minato City's checklist asks for a record of prior consultation with the fire authority, and Toshima City's explanation asks for a document showing that you consulted the fire authority and, where applicable, proof of the filing under Article 17-3-2 of the Fire Service Act
- When work or a layout change turns the use from housing to lodging, the Tokyo Fire Department asks for a construction plan notice at least 7 days before the work and a notice of start of use at least 7 days before opening, plus installation notices for fire equipment
A workable order is: consult the fire station with floor plans before signing; agree on the required equipment; arrange the work and the related notices; have the fire station check the property; then file the minpaku notification with the documents the ward requires. Yokohama City's fire bureau, for example, also advises contacting the nearest fire station before filing.
The Japan Tourism Agency states that a minpaku must comply with fire laws and directs operators to the ward and the local fire station for details. → What to check before buying
How we can help
Kreis Networks is a registered residential lodging management business (Ministry of Land, Infrastructure, Transport and Tourism) and a licensed real estate broker in Tokyo. For properties we manage, we can arrange and attend the fire station consultation, coordinate equipment work with contractors, and keep inspections and records in order. Final decisions on requirements are made by the fire station, and we can share what we learn in the consultation with you in English. We accept inquiries in English through our contact form and reply by email.